Angiotensin Converting Enzyme (ACE) Kinetic Assay in serum BÜHLMANN ACE Kinetic 1200 tests diagnosis and monitoring of sarcoidosis
Product code: KK-ACKX
- List Price
- £2,979.94
This is not a regular stock item and therefore not subject to our standard delivery schedule. Please contact us on +44 (0) 2380 483000 for advice on expected delivery date.
Call UsProduct Information
The BÜHLMANN ACE kinetic assay uses the synthetic ACE substrate, FAPGG. The ACE present in the sample cleaves the FAPGG into an amino acid derivative and a dipeptide which results in a decrease in absorbance at 340nm. The change in absorbance over a given time period can then be used to calculate the Angiotensin Converting Enzyme activity in the sample. The assay is supplied complete with calibrator and QC materials and provides a linear assay up to 150U/L. The substrate reagent is supplied as a ready-to-use, stable liquid but calibrator and controls are provided in a lyophilised state and reconstituted are stable for up to 6 months when stored at 2-8C.
Additional calibrator and controls are available separately. This assay should be performed on serum samples and is suitable for manual and automated protocols.
Product Details:
Product code: KK-ACKX
Sample type: Serum. Since EDTA inhibits ACE activity, serum specimen should be used for the determination of ACE activity.
Collect sufficient blood (at least 0.5 ml) by venipuncture into an appropriate tube without anticoagulant. coagulate for 2-3 hours at room temperature, centrifuge at 4°C and 1000 x g and collect the serum. Freeze the serum specimen at –20°C if not assayed within 5 days. ACE activity in sterile serum is stable for up to 30 days at 2-8°C and 6 months at –20°C. To avoid lipemic sera, blood samples should be taken from fasting patients. Due to interference with the photometric determination, lipemic sera must be pre-treated either with an Ultracentrifuge or with LipoClear from StatSpin Inc. (www.statspin.com). Icteric or hemolytic sera can not be used for ACE activity determination.
Sample volume: 25µl
CE marked: Yes
Number of tests: 1200
CE certified protocols for: Abbott Aeroset, Bayer Advia 2400, Beckman Synchron Cx, Beckman Synchron Lx/UniCel DxC, Dade Dimension RxL, Kone T-series, Olympus AU640/400, Olympus AU 480, Olympus AU2700/5400, Roche Hitachi 911, Roche Cobas Integra, Roche Cobas Mira, Roche c501, Roche Cobas 6000/8000, Roche Modular P800
Specification
- Brand BÜHLMANN
- Sterile
- CE Certified CE IVD
- Warranty Period Standard Terms Apply
- Is product classified as dangerous goods? No
- Does the product contain latex?
- Measuring range 12 - 150U/l
- Sensitivity 12U/l
- Detected chemical Angiotensin Converting Enzyme
- Type Serum ACE
Storage Details
- Pack Description 1200 tests
- Shipping Condition
- Storage Condition
- Pack Length (m) 0.22
- Pack Width (m) 0.1
- Pack Height (m) 0.12
- Pack Weight (kg) 2.00